Solutions to Inadequate Flow Rate of Metering Pump
Time:2019-01-22 01:41:09 Browse:3575

After the metering pump is installed, we hope to be able to run normally, which can reduce many costs, but sometimes the metering pump is running without water or insufficient flow, so what causes such a situation to occur, and how to solve this problem, the small part introduces to you.

1. Reasons and solutions of metering pump failing to discharge water:
1. The inlet and outlet valves are not opened, the inlet and outlet pipelines are blocked, and the abortion impellers are blocked. The solution is to remove the blockage.
2. Hot water pump suction pipe leaks. Tighten each sealing surface to remove air.
3. The running direction of the motor is not right, and the speed of the motor without phase is very slow. Adjust the direction of the motor and strengthen the connection of the motor.
4. The metering pump is not filled with liquid and there is air in the pump chamber. Open the top cover of the pump or the exhaust valve to exhaust the air.
5. Import and export water supply is insufficient, suction range is too high, bottom valve leaks. Inspection and adjustment of shutdown (this phenomenon is easy to occur in the use of water pipes connected to the grid and with suction range).
6. Pipeline resistance is too large, and the selection of centrifugal pump is inappropriate. Reduce pipe bends and re-select pumps.

2. Reasons for insufficient flow of metering pumps and how to solve them:
1. The inlet and outlet valves are not opened, the inlet and outlet pipelines are blocked, and the abortion impellers are blocked. The solution is to remove the blockage.
2. The impellers of pipes and runners are partially blocked, and the scale deposits and the opening of valves are insufficient. Remove obstruction and adjust valve opening.
3. Low voltage of metering pump. Voltage stabilizing
4. Impeller wear. Replace the impeller.
5. Use above rated flow rate. Adjust flow and turn off outlet valve
6. Excessive suction. Reduce the suction distance.
7. Wear of pump bearing. Replace bearings.

CONTACT
Join:All the products of our company are for the whole country to recruit agents. If you want to join in business and order, please contact us by the following ways.
13771177635Mr. Liu
13921516709Mr. Zhao
Email
sales@yuanshuflow.com
Room 201-1, Famous Creative Intelligence Park,
501 Nanhu Avenue, Liangxi District, Wuxi City

Focus on Wechat Public Number

Focus on Mobile Official Website
Copyright © 2019 Wuxi YuanShu Intelligent Fluid Technology Co., Ltd. All Rights Reserved   備案號:蘇ICP備19004024號
主站蜘蛛池模板: 无为县| 越西县| 肥乡县| 昭觉县| 辉县市| 静海县| 莱州市| 略阳县| 淳安县| 武威市| 通辽市| 鹿邑县| 手游| 万州区| 六枝特区| 白银市| 昌乐县| 肃南| 安福县| 八宿县| 托里县| 昭苏县| 凤翔县| 双柏县| 嘉峪关市| 平乐县| 鹤壁市| 巫溪县| 浪卡子县| 宁阳县| 深州市| 桃园县| 乌鲁木齐市| 卓尼县| 吉水县| 聂拉木县| 肃宁县| 抚远县| 荔波县| 宜城市| 高清|